This is the latest recevied telemetry packets stored in our database for station/object EA5KAO-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Voltage* | Celsius* | Rel_Hum* | Atm_Press* | Value5* |
|---|---|---|---|---|---|
| 1762811600 | 4.01 VDC | 24.4 C | 41.05 % | 1020.25 hPa | 0 |
| 1762810697 | 4.01 VDC | 24.4 C | 40.91 % | 1018.75 hPa | 0 |
| 1762809794 | 4.02 VDC | 24.4 C | 41.22 % | 1017.13 hPa | 0 |
| 1762808891 | 4.02 VDC | 24.3 C | 41.25 % | 1021.13 hPa | 0 |
| 1762807988 | 4.02 VDC | 24.2 C | 41.54 % | 1022.5 hPa | 0 |
| 1762807085 | 4.02 VDC | 24.2 C | 41.47 % | 1019.38 hPa | 0 |
| 1762806182 | 4.03 VDC | 24.2 C | 42.02 % | 1018.38 hPa | 0 |
| 1762805279 | 4.03 VDC | 24.2 C | 42.28 % | 1021.13 hPa | 0 |
| 1762804376 | 4.04 VDC | 24.2 C | 42.41 % | 1019.63 hPa | 0 |
| 1762797018 | 4.19 VDC | 23.8 C | 40.51 % | 1014.63 hPa | 0 |
| 1762796118 | 4.19 VDC | 24 C | 39.75 % | 1016 hPa | 0 |
| 1762795212 | 4.19 VDC | 23.9 C | 39.13 % | 1016.38 hPa | 0 |
| 1762783473 | 4.19 VDC | 24.1 C | 37.11 % | 1016.13 hPa | 0 |
| 1762782570 | 4.19 VDC | 23.9 C | 38.01 % | 1016.63 hPa | 0 |
| 1762769032 | 4.19 VDC | 22.6 C | 39.87 % | 1017.5 hPa | 0 |
| 1762764510 | 4.19 VDC | 22 C | 40.79 % | 1021.13 hPa | 0 |
| 1762761801 | 4.19 VDC | 22 C | 40.91 % | 1021.63 hPa | 0 |
| 1762759995 | 4.19 VDC | 22.1 C | 41.39 % | 1016.25 hPa | 0 |
| 1762753674 | 4.19 VDC | 22.3 C | 38.76 % | 1017.25 hPa | 0 |
| 1762752771 | 4.19 VDC | 22.3 C | 38.51 % | 1017.25 hPa | 0 |
| 1762751868 | 4.19 VDC | 22.4 C | 38.6 % | 1018.13 hPa | 0 |
| 1762744644 | 4.19 VDC | 22.8 C | 38.4 % | 1016 hPa | 0 |
| 1762741934 | 4.19 VDC | 23 C | 38.87 % | 1017 hPa | 0 |
| 1762741032 | 4.19 VDC | 23 C | 38.79 % | 1018 hPa | 0 |
| 1762740128 | 4.19 VDC | 23.1 C | 38.94 % | 1021.5 hPa | 0 |
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)