This is the latest recevied telemetry packets stored in our database for station/object LX1LW-10. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
Time | V_Batt* | V_Ext* | Value3* | Value4* | Value5* |
---|---|---|---|---|---|
1754225791 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754224891 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754223991 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754223091 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754222191 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754221291 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754220390 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754219490 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754218590 | 5.06 VDC | 0.7 VDC | 0 | 0 | 0 |
1754217690 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754216790 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754215890 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754214990 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754214090 | 5.06 VDC | 0.72 VDC | 0 | 0 | 0 |
1754213190 | 5.06 VDC | 0.74 VDC | 0 | 0 | 0 |
1754212289 | 5.06 VDC | 0.74 VDC | 0 | 0 | 0 |
1754211389 | 5.06 VDC | 0.76 VDC | 0 | 0 | 0 |
1754210489 | 5.06 VDC | 0.74 VDC | 0 | 0 | 0 |
1754209589 | 5.06 VDC | 0.68 VDC | 0 | 0 | 0 |
1754208689 | 5.06 VDC | 0.76 VDC | 0 | 0 | 0 |
1754207789 | 5.06 VDC | 0.74 VDC | 0 | 0 | 0 |
1754206889 | 5.06 VDC | 0.76 VDC | 0 | 0 | 0 |
1754205989 | 5.06 VDC | 0.76 VDC | 0 | 0 | 0 |
1754205089 | 5.06 VDC | 0.78 VDC | 0 | 0 | 0 |
1754204188 | 5.06 VDC | 0.78 VDC | 0 | 0 | 0 |
*Used Equation Coefficients:
V_Batt: 0, 0.01, 0
V_Ext: 0, 0.02, 0
Value3: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)