This is the latest recevied telemetry packets stored in our database for station/object DL6DBZ-9. If no packets are shown the sender has not sent any telemetry packets the latest 1 day(s).
Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).
| Time | Celsius* | Rel_Hum* | Atm_Press* | GAS* | Value5* |
|---|---|---|---|---|---|
| 1790138434 | 23.6 C | 41.65 % | 1026.38 hPa | 52.69 % | 0 |
| 1790138386 | 23.6 C | 41.05 % | 1028.88 hPa | 50.71 % | 0 |
| 1790138370 | 23.6 C | 41.05 % | 1027.25 hPa | 50.71 % | 0 |
| 1790138352 | 23.6 C | 40.49 % | 1032 hPa | 49.73 % | 0 |
| 1790138335 | 23.6 C | 40.49 % | 1029.88 hPa | 49.73 % | 0 |
| 1790138318 | 23.6 C | 40.49 % | 1027.38 hPa | 49.73 % | 0 |
| 1790138301 | 23.5 C | 40.05 % | 1032.88 hPa | 46.13 % | 0 |
| 1790138236 | 23.5 C | 40.1 % | 1030 hPa | 41.69 % | 0 |
| 1790138219 | 23.5 C | 40.1 % | 1027.88 hPa | 41.69 % | 0 |
| 1790138194 | 23.5 C | 40.1 % | 1025.38 hPa | 41.69 % | 0 |
| 1790138177 | 23.5 C | 40.31 % | 1030.75 hPa | 39.41 % | 0 |
| 1790138160 | 23.5 C | 40.31 % | 1032 hPa | 39.41 % | 0 |
| 1790138118 | 23.6 C | 40.61 % | 1031 hPa | 35.4 % | 0 |
| 1790138101 | 23.6 C | 40.61 % | 1030.13 hPa | 35.4 % | 0 |
| 1790138085 | 23.6 C | 40.61 % | 1028.13 hPa | 35.4 % | 0 |
| 1790138069 | 23.6 C | 40.61 % | 1026.38 hPa | 35.4 % | 0 |
| 1790138008 | 23.6 C | 40.87 % | 1024.38 hPa | 32.15 % | 0 |
| 1790137842 | 23.9 C | 42.9 % | 1025.75 hPa | 19.31 % | 0 |
| 1790137634 | 24.1 C | 42.26 % | 1026.88 hPa | 12.51 % | 0 |
| 1790137592 | 24.3 C | 43.06 % | 1027.75 hPa | 9.25 % | 0 |
| 1790137566 | 24.3 C | 43.06 % | 1027.25 hPa | 9.25 % | 0 |
| 1790137538 | 24.3 C | 44.24 % | 1028.5 hPa | 9.79 % | 0 |
| 1790137439 | 24.3 C | 45.32 % | 1025.75 hPa | 8.54 % | 0 |
| 1790137331 | 24.4 C | 45.01 % | 1022.88 hPa | 12.51 % | 0 |
| 1790137300 | 24.4 C | 45.69 % | 1026.38 hPa | 15.67 % | 0 |
*Used Equation Coefficients:
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
GAS: 0, 0.01, 0
Value5: 0, 1, 0
- The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
- Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
The sent equation coefficients is used in the equation: a * value2 + b * value + c. - The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
- The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
- All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
- A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)